Product List
     
  
Home > News
What is the reason why the carton of the cartoning machine is not sucked down?
Analysis of the main reasons why the carton of the cartoning machine is not sucked down
First, please check the following six items one by one:
(1) The air path is blocked or leaked;
(2) The suction cup is aging and rigid;
(3) Improper adjustment of the carton stacking rack;
(4) The carton sticks;
(5) The vacuum pressure is insufficient (the original pressure is insufficient);
(6) The time of inhalation and apnea is wrong

Solution to the problem
(1) Check the pipeline carefully to prevent leakage;
(2) Replace the suction cup;
(3) Readjust the position of the carton stacking rack;
(4) Loosen the paper box or replace the paper box;
(5) Add atmospheric pressure (vacuum degree above 4 Pa);
(6) Re-adjust the inhalation time